Model 5832 Critical Environment Benchtop Blower

下載文件 產品查詢

The Simco-Ion Critical Environment Benchtop Blower Model 5832 provides reliable, fast static charge control for benchtop work areas and small spaces, allowing optimal electrostatics management that minimizes cost and maximizes protection for ESD-sensitive areas. An internal automatic balance correction system ensures ionization continues to reach your target with complete accuracy presenting a significant time and cost savings.

The ionizer can operate with an external sensor to maintain precise balance (better than ±1V) by altering ion output and adapting to environment changes. With the optional remote sensor or Novx feedback/ control, the Model 5832 delivers precisely balanced and directed ionized air to your target without taking up valuable room in your environment. A greater concentration of emitter points and internal circuitry suited for high humidity applications makes the Model 5832 the standard choice for environments that need quality ESD protection with solid design.


Features:

  • ±3V or better balance (±1V with the optional external feedback system)
  • Cleanliness rated at ISO 14644 Class 4 (Fed. Std. 209e Class 10)
  • Options for sensor input, FMS connection, alarms, and management control
  • Auto-Clean System


Benefits:

  • Provides the best corona-based ESD protection for maximizing yields
  • Designed for use in an environment with a controlled level of contamination
  • Increased control with immediate notification of alarms and the prevention of unauthorized adjustment to power or fan speed
  • Automates emitter point cleaning, reducing maintenance costs and time


Specifications:

Model 5832 Ionizer 
 Input Voltage  24 VDC (470 mA max)
 Discharge1  Better than 2 sec @ 1ft (typ), taken in-line from the center of the fan (±1000-100V);
 Balance  Better than ± 1V (typ) with external sensor; ±3V (typ) without sensor
 Ion Emission  Steady-state DC (corona discharge)
 Emitter Points  ISO 14644 Class 4 (Fed. Std. 209e Class 10) titanium, 8 per fan
 Airflow  129 cfm (typ)
 Cleanroom Class  Meets ISO 14644-1 Class 4 (Fed. Std. 209E Class 10)
 Operating Env.  Temperature 50-90ºF (10-32ºC); humidity 30-70% RH, non-condensing
 Ozone  0.005 ppm (typ)
 LED Indicators  Green POWER on, red FAULT alarm with optional AUDIBLE ALARM 
 Audible Noise  High fan speed 61 dB (typ); low fan speed 52 dB (typ); measurements taken 
 12" (30.5cm) from fan
 Mounting  Tilt Lock Mounting Stand
 Controls  Power/fan speed DIP switch with 4 speed/velocity settings, balance adjustment, 
 sensor type selection and FMS connections
 Options  External sensor inputs with FMS connection, audible alarm,
 Enclosure  Aluminum chasis with epoxy-polyester powder coat
 Dimensions  7.27H x 5.12W x 2.76D in. (18.5H x 13W x 7.0D cm)
 Weight  2.2 lb (1 kg)
 Warranty  Two year limited warranty
 Certifications  

 

 Power Adapter 14-21327
 Input Voltage  100-240 VAC 50/60 Hz
 Output Voltage  24 VDC, 60W
 Dimensions  4H x 1.9W x 1.1D in. (103 x 42 x29 mm)
 Weight  5 oz (140g)
 Certifications  
 

1. Tested in accordance with ANSI/ESD STM3.1-2015.

        
            
±1V Balance Performance
Novx Option: The Model 5832’s optional external feedback sensor operates with the Novx 7000 Process Monitor and with the Novx 3352 Passive or Novx 3362 Active Closed-loop Ionizer Controllers to detect and automatically correct the balance. With the antenna placed at the target area, feedback is sent to the Model 5832 blower’s internal control system (RJ Connector). This ensures that your target maintains a ±1V or better balance at all times.

Remote Antenna Option: The Model 5832 can be ordered and operated with the remote antenna option which allows any of the standard Novx Passive Antenna assemblies to be connected directly to the 5832 (SMA Connector).

DIP Switch Settings
 Switch  Description
1  SENSOR: This switch zero’s the front grill and remote sensor   inputs to eliminate offsets caused by the circuitry when the   remote sensor is used.
2  EPC Auto/Man: The third dip switch sets the emitter point   cleaner to run on a timer (Auto) or only when the external input   is manually activated from the IO terminal block input (Man).
3,4  Fan Speed Switch: The remaining 2 dip switches control the fan   speed; 4 speeds are available. The switch settings for each fan   speed are listed in the table below.


Adaptable Options

  • An audible alarm that operates in addition to the visible array of 3 each LED’s on the front of the blower indicate operational failures including a stalled fan or loss of ionization.
  • The Auto-Clean System, which reduces maintenance periods by sweeping the emitter points when the blower is turned off and on or on a preset time interval or user activated through the FMS.


Ordering Information

 91-5832-01  5832 Blower, Standard
 91-5832-01A  5832 Blower Standard with Audible Alarm
 91-5832A-01  5832 Blower with Antenna Connection
 91-5832A-01A  5832 Blower Standard with Antenna Connection and Audible Alarm
 91-5832N-01  5832 Blower with Novx Connection
 91-5832N-01A  5832 Blower Standard with Novx Connection and Audible Alarm
 14-21327  Power Adapter
 33-1620-xx  IC, Novx feedback/Control Interface Cable
 33-0504  Passive Antenna, 1.75" x 4" Tall with SMA-to-SMA Cable (5 ft)
 33-0521-5  Passive Antenna, 1.75" x 1" Tall with SMA-to-SMA Cable (5 ft)